Flow injection chemiluminescence method for determination of acarbose

  • ZHAO Mian ,
  • WANG Beibei ,
  • WANG Bing ,
  • LI Xianrui
Expand
  • 1.Experimental Center for Teaching, Hebei Medical University, Shijiazhuang 050017, China; 2.College of Pharmacy, Hebei Medical University, Shijiazhuang 050017, China

Received date: 2021-10-20

  Online published: 2022-06-16

Abstract

A simple and rapid flow-injection chemiluminescence(FI-CL)method was developed for the determination of acarbose in tablets based on the fact that acarbose can remarkably enhance the chemiluminescence of Luminol-H2O2 in alkaline medium. The determination conditions were optimized. Under optimum conditions, the chemiluminescence relative intensity had a good linear relationship with acarbose concentration in the range of 3×10-4~2×10-2 mg/mL with a correlation coefficient of 0.998 7. The detection limit was 2.3×10-4 mg/mL and RSD(n=11)is 2.7% for 0.01 mg/mL acarbose. The proposed method has been successfully applied for the determination of acarbose in tablets sample and the average recovery was 101.6%.

Cite this article

ZHAO Mian , WANG Beibei , WANG Bing , LI Xianrui . Flow injection chemiluminescence method for determination of acarbose[J]. Journal of Hebei University(Natural Science Edition), 2022 , 42(3) : 251 -255 . DOI: 10.3969/j.issn.1000-1565.2022.03.005

References

[1] 姚佳舒,孙子林,袁杨. 2型糖尿病降糖药物治疗进展:更加关注心血管及肾脏结局[J].中国糖尿病杂志, 2021, 29(3): 224-228. DOI: 10.3969/j.issn.1006.
[2] 朱月霞,邵仲柏,吴小小,等.海洋天然产物中α-葡萄糖苷酶抑制剂研究进展[J].南京中医药大学学报, 2021, 37(2): 311-320. DOI:10.14148/j.issn.1672-0482.2021.0311.
[3] 赖晓红,李敏,周燕,等.基于HPLC-MS/MS快速筛选阿卡波糖及其类似物的菌株[J].质谱学报, 2021, 42(1): 48-55. DOI: 10.7538/zpxb.2019.0175.
[4] 赵慧.HPLC-CAD法测定阿卡波糖胶囊含量[J].药物分析杂志, 2020, 40(5): 910-915. DOI:10.16155/j.0254-1793.2020.05.19.
[5] LIU Y Y, LI H M, LU L, et al. A Ratiometric electrochemical sensor with integrated probe for the assay of α-glucosidase activity and screening of its inhibitors[J]. Journal of the Electrochemical Society B, 2019, 166(2):133-140. DOI: 10.1149/2.1111902jes.
[6] TIMUR S, ÜLKÜ ANIK. Alpha-glucosidase based bismuth film electrode for inhibitor detection[J]. Analytica Chimica Acta, 2007, 598(1):143-146. DOI: 10.1016/j.aca.2007.07.019.
[7] SHI M L, CEN Y, XU G H, et al. Ratiometric fluorescence monitoring of α-glucosidase activity based on oxidase-like property of MnO2 nanosheet and its application for inhibitor screening[J]. Analytica Chimica Acta, 2019, 1077:225-231. DOI: 10.1016/j.aca.2019.05.037.
[8] ZHANG H, WANG Z, YANG X Q, et al. The determination of α-glucosidase activity through a nano fluorescent sensor of F-PDA-CoOOH[J]. Analytica Chimica Acta, 2019, 1080: 170-177. DOI: 10.1016/j.aca.2019.07.014.
[9] KONG W H, WU D, XIA L, et al. Carbon dots for fluorescent detection of α-glucosidase activity using enzyme activated inner filter effect and its application to anti-diabetic drug discovery[J]. Analytica Chimica Acta, 2017, 973:91-99. DOI: 10.1016/j.aca.2017.03.050.
[10] TANG C, QIAN Z S, QIAN Y J, et al. A fluorometric and real-time assay for α-glucosidase activity through supramolecular self-assembly and its application for inhibitor screening[J]. Sensors and Actuators B, 2017, 245:282-289. DOI: 10.1016/j.snb.2017.01.150.
[11] LI G L, KONG W H, ZHAO M, et al. A fluorescence resonance energy transfer(FRET)based “Turn-On” nanofluorescence sensor using a nitrogen-doped carbon dot-hexagonal cobalt oxyhydroxide nanosheet architecture and application to α-glucosidase inhibitor screening[J]. Biosensors and Bioelectronics, 2016, 79:728-735. DOI: 10.1016/j.bios.2015.12.094.
[12] LIU D M, DONG C, MA R T. A colorimetric method for screening α-glucosidase inhibitors from flavonoids using 3, 3', 5, 5'-tetramethylbenzidine as a chromogenic probe[J]. Colloids and Surfaces B, 2021, 197:1-6. DOI: 10.1016/j.colsurfb.2020.111400.
[13] CHENG X, HUANG Y, YUAN C, et al. Colorimetric detection of α-glucosidase activity based on the etching of gold nanorods and its application to screen anti-diabetic drugs[J]. Sensors and Actuators B, 2019, 282(3):838-843. DOI: 10.1016/j.snb.2018.11.097.
[14] KONG W H, WU D, HU N, et al. Robust hybrid enzyme nanoreactor mediated plasmonic sensing strategy for ultrasensitive screening of anti-diabetic drug[J]. Biosensors and Bioelectronics, 2018, 99: 653-659. DOI: 10.1016/j.bios.2017.08.009.
[15] CHEN H X, ZHANG J J, WU H, et al. Sensitive colorimetric assays for α-glucosidase activity and inhibitor screening based on unmodified gold nanoparticles[J]. Analytica Chimica Acta, 2015, 875:92-98. DOI:10.1016/j.aca.2015.02.022.
[16] 李献锐,王娜,王贝贝,等. 流动注射-化学发光法测定饲料中环丙氨嗪[J]. 分析科学学报, 2020, 36(3):439-442. DOI:10.13526/j.issn.1006-6144.2020.03.023. (
Outlines

/

〈 〉