Journal of Hebei University (Natural Science Edition) ›› 2018, Vol. 38 ›› Issue (2): 133-139.DOI: 10.3969/j.issn.1000-1565.2018.02.004

Previous Articles     Next Articles

Finite element simulation of metal plate crack defect

TIAN Xiao,HAO Yuqiang,MA Yan,LI Yanan,ZHOU Qianqian,LIANG Yan   

  1. Non-destructive Testing Labratory, College of Quality and Technology Supervision, Hebei University, Baoding 071002, China
  • Received:2017-10-10 Online:2018-03-25 Published:2018-03-25

Abstract: In this paper,the ansys simulation analysis on aluminum alloy plate,copper plate,and stainless steel plate under the different frequencies with the same artificial defects were carried out.Through the analysis of the magnetic field lines in the electromagnetic field distribution,the test gives the real and the imaginary part of the current,and the corresponding impedance map is obtained.The simulation result points out that the impedance of the coil is changed due to the resistivity,frequency and defects.The conclusion is valuable for practical testing.

Key words: eddy current testing, ansys stimulation technology, defects, excitation frequency

CLC Number: