[1] 祝志祥,韩钰,惠娜,等.高压直流输电接地极材料的应用现状与发展[J].华东电力,2012,40(2):265-269. ZHU Z X,HAN Y,HUI N,et al.Application status and development of HVDC grounding materials[J].East China Electric Power,2012,40(2):0265-0269. [2] 陈坤汉,杨道武,喻林萍,等.电力接地网土壤腐蚀性的评价[J].腐蚀与防护,2008,29(10):614-617. CHEN K H,YANG D Y,YU L P,et al.Evaluation of soil corrosivity of electric power grounding grid[J].Corrosion and Protection.2008,29(10):614-617. [3] 翁永基,李相怡.交流阻抗谱技术用于研究塔中沙漠油田接地材料的腐蚀行为[J].石油大学学报(自然科学版),1999,23(4):49-52. WENG Y J,LI X Y.Study of earth materials in tarim oilfield by the corrosion behavior of ac impedance spectroscopy[J].Journal of China University of Petroleum(Edition of Natural Science),1999,23(4):49-52. [4] 范璇,王建国,周蜜,等.接地材料腐蚀速度弱极化曲线评价方法[J].中国电机工程学报,2012,32(28):192-198. FAN X,WANG J G,ZHOU M,et al.Evaluation of ground material corrosion rate by weak polarization curve method[J].Proceedings of the CSEE,2012,32(28):192-198. [5] W V. 贝克曼,W. 施文克,著.阴极保护手册[M].胡士信等译.北京:人民邮电出版社,2005:11-17. [6] 左景伊,左禹.腐蚀数据与选材手册[M].北京:化学工业出版社,1995:1-5. [7] 张攀峰,於孝春.受直流杂散电流影响埋地管线的AN-SYS模拟[J].腐蚀与防护,2011,32(2):146-149. ZHANG P F,YU X C.AN-SYS Simulation of buried pipelines on the effect of dc stray current[J].Corrosion and Protection,2011,32(2):146-149. [8] ATTIA M S,RAGAB A R,ELRAGHY S.Failure analysis of buried piping and cold drain vessel[J].Eng Failure Anal,2011,18(3):933-943.DOI:10.1016/j.engfailanal.2010.11.011 [9] BERTOLINI L,CARSANA M,PEDEFERRI P.Corrosion behavior of steel in concrete in the presence of stray current[J].Corros.Sci.,2007,49(3):1056-1068.DOI:10.1016/j.corsci.2006.05.048 [10] FU A Q,CHENG Y F.Effects of alternating current on corrosion of a coated pipeline steel in a chloride-containing carbonate/bicarbonate solution[J].Corros Sci,2010,52(2):612-619.DOI: 0.1016/j.corsci.2009.10.022 [11] 姜子涛,杜艳霞,董亮,等.交流电对Q235钢腐蚀电位的影响规律研究[J].金属学报,2011,47(8):997-1002. JIANG Z T,DU Y X,DONG L,et al.Effect of ac current on corrosion potential of q235 steel[J].Acta Metallurgica Sinica,2011,47(8):997-1002. [12] 杜晨阳,曹备,吴荫顺.交流电干扰下-850 mV(SCE)阴极保护电位准则的适用性研究[J].腐蚀与防护,2009,30(9):655-659. DU C Y,CAO B,WU Y S.The applicability of the -850 mv(sce)cathodic protection potential criterion under ac interference[J].Corrosion and Protection,2009,30(9):655-659. [13] 李自力,丁清苗,张迎芳,等.用电化学方法建立交流干扰下X70钢的最佳阴极保护电位[J].腐蚀与防护,2010,31(6):436-439. LI Z L,DING Q M,ZHANG Y F,et al.The establishment of optimal cathodic protection potential of x70 steel under ac interference by electrochemical method[J].Corrosion and Protection,2010,31(6):436-439. [14] 李福军,路民旭,陈月勋.大庆油田电泵井套管杂散电流腐蚀测试分析[J].材料保护,2008,41(10):66-67. LI F J,LU M X,CHEN Y X.Stray current corrosion test and analysis of daqing oilfield electric pump oil wells[J].Material Protection,2008,41(10):66-67. [15] 张玉星,杜艳霞,路民旭.动态直流杂散电流干扰下埋地管道的腐蚀行为[J].腐蚀与防护,2013,34(9):771-774. ZHANG Y X,DU Y X,LU M X.The corrosion behavior of buried pipelines under dynamic dc stray current interference[J].Corrosion and Protection,2013,34(9):771-774. [16] 宋吟蔚,王新华,何仁洋,等.埋地钢质管道杂散电流腐蚀研究现状[J].腐蚀与防护,2009,30(8):515-518. SONG Y W,WANG X H,HE R Y,et al.present situation of research on buried steel pipeline stray current corrosion[J].Corrosion and Protection,2009,30(8):515-518. [17] Barlo D T J,Zdunek D A D.Stray current corrosion in electrified rail systems[R].1995. [18] 邵建人,乐晏廷.交流系统接地网的腐蚀与防护研究[J].电力设备,2006,7(4):70-72. SHAO J R,LE Y T.Study on corrosion and protection of ac system grounding grid[J].Power Equipment,2006,7(4):70-72. [19] 李健,苏航,闫爱军,等.耐酸性土壤腐蚀接地网用钢研究[J].腐蚀科学与防护技术,2015,27(2):116-122. LI J,SU H,YAN A J,et al.Acid soil corrosion resistance of grounding steel research[J].Corrosion Science and Protection Technology,2015,27(2):116-122. [20] 许建国.浅谈杂散电流腐蚀机理及防护措施[J].铁道机车车辆,2005,25(3):61-64. XU J G.Introduction of the stray current corrosion mechanism and prevention measures[J].Railway Locomotive & CAR,2005,25(3):61-64. [21] RP0169—2002,Control of external corrosion on underground or submerged metallic piping system[S]. [22] 杜翠薇,王胜荣,刘智勇,等.Q235钢与X70钢在新加坡土壤环境中1年腐蚀行为研究[J].腐蚀科学与防护技术,2015,27(3):231-236. DU C W,WANG S R,LIU Z Y,et al.Research on corrosion behavior of q235 seel and x70 steel in singapore soil for one year[J].Corrosion Science and Protection Technology,2015,27(3):231-236. [23] 吴向东.500kV输电线路接地网腐蚀分析及防护措施[J].腐蚀与防护,2002,23(12):545-547. WU X D.Grounding grid corrosion analysis and protection measures for 500 kV transmission line[J].Corrosion and Protection,2002,23(12):545-547. [24] 尹国耀,魏振宏.杂散电流腐蚀与防护[J].焊管,2008,31(4):74-76. YI G Y,WEI Z H.Stray current corrosion and protection[J].Welded Pipe And Tube,2008,31(4):74-76. |